1 # Author: Gray Putnam <grayputnam@uchicago.edu>
2 # Include this file at the bottom of any fhicl file handling MC with 3 drift windows.
3 # It will modify all services parameters necessary.
5 services.DetectorPropertiesService.NumberTimeSamples: 7800 # 3 drift windows
6 services.DetectorPropertiesService.ReadOutWindowSize: 7800
8 # run g4 for the 0.2ms rise time + one full drift window + 1st readout window before neutrino arrives
9 # (one drift window = 1.25ms)
10 services.DetectorClocksService.G4RefTime: -2.8e3 # [us]
12 # TPC readout starts one readout window before the neutrino arrives (which we set to t0)
13 services.DetectorClocksService.TriggerOffsetTPC: -1.3e3 # [us]
15 # set neutrino arrival time
16 services.DetectorClocksService.DefaultTrigTime: 2.8e3 # [us]
17 services.DetectorClocksService.DefaultBeamTime: 2.8e3 # [us]
BEGIN_PROLOG triggeremu_data_config_icarus settings PMTADCthresholds sequence::icarus_stage0_multiTPC_TPC physics sequence::icarus_stage0_EastHits_TPC physics sequence::icarus_stage0_WestHits_TPC physics producers purityana0 caloskimCalorimetryCryoE physics caloskimCalorimetryCryoW physics sequence::physics pathW services